1.
Sci Rep ; 13(1): 8105, 2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-37248245

RESUMO

We propose an ultra-low-cost at-home blood pressure monitor that leverages a plastic clip with a spring-loaded mechanism to enable a smartphone with a flash LED and camera to measure blood pressure. Our system, called BPClip, is based on the scientific premise of measuring oscillometry at the fingertip to measure blood pressure. To enable a smartphone to measure the pressure applied to the digital artery, a moveable pinhole projection moves closer to the camera as the user presses down on the clip with increased force. As a user presses on the device with increased force, the spring-loaded mechanism compresses. The size of the pinhole thus encodes the pressure applied to the finger. In conjunction, the brightness fluctuation of the pinhole projection correlates to the arterial pulse amplitude. By capturing the size and brightness of the pinhole projection with the built-in camera, the smartphone can measure a user's blood pressure with only a low-cost, plastic clip and an app. Unlike prior approaches, this system does not require a blood pressure cuff measurement for a user-specific calibration compared to pulse transit time and pulse wave analysis based blood pressure monitoring solutions. Our solution also does not require specialized smartphone models with custom sensors. Our early feasibility finding demonstrates that in a validation study with N = 29 participants with systolic blood pressures ranging from 88 to 157 mmHg, the BPClip system can achieve a mean absolute error of 8.72 and 5.49 for systolic and diastolic blood pressure, respectively. In an estimated cost projection study, we demonstrate that in small-batch manufacturing of 1000 units, the material cost is an estimated $0.80, suggesting that at full-scale production, our proposed BPClip concept can be produced at very low cost compared to existing cuff-based monitors for at-home blood pressure management.


Assuntos
Determinação da Pressão Arterial , Smartphone , Humanos , Pressão Sanguínea/fisiologia , Monitores de Pressão Arterial , Calibragem , Análise de Onda de Pulso
2.
Res Sq ; 2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36909577

RESUMO

We propose BPClip, a less than $ 1 USD blood pressure monitor that leverages a plastic clip with a spring-loaded mechanism to enable any smartphone with a flash LED and a camera to measure blood pressure. Unlike prior approaches, our system measured systolic, mean, and diastolic blood pressure using oscillometric measurements that avoid cumbersome per-user calibrations and does not require specialized smartphone models with custom sensors.

3.
NPJ Digit Med ; 5(1): 146, 2022 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-36123367

RESUMO

Hypoxemia, a medical condition that occurs when the blood is not carrying enough oxygen to adequately supply the tissues, is a leading indicator for dangerous complications of respiratory diseases like asthma, COPD, and COVID-19. While purpose-built pulse oximeters can provide accurate blood-oxygen saturation (SpO2) readings that allow for diagnosis of hypoxemia, enabling this capability in unmodified smartphone cameras via a software update could give more people access to important information about their health. Towards this goal, we performed the first clinical development validation on a smartphone camera-based SpO2 sensing system using a varied fraction of inspired oxygen (FiO2) protocol, creating a clinically relevant validation dataset for solely smartphone-based contact PPG methods on a wider range of SpO2 values (70-100%) than prior studies (85-100%). We built a deep learning model using this data to demonstrate an overall MAE = 5.00% SpO2 while identifying positive cases of low SpO2 < 90% with 81% sensitivity and 79% specificity. We also provide the data in open-source format, so that others may build on this work.

5.
Sci Rep ; 12(1): 3463, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35236896

RESUMO

Early detection of diseases such as COVID-19 could be a critical tool in reducing disease transmission by helping individuals recognize when they should self-isolate, seek testing, and obtain early medical intervention. Consumer wearable devices that continuously measure physiological metrics hold promise as tools for early illness detection. We gathered daily questionnaire data and physiological data using a consumer wearable (Oura Ring) from 63,153 participants, of whom 704 self-reported possible COVID-19 disease. We selected 73 of these 704 participants with reliable confirmation of COVID-19 by PCR testing and high-quality physiological data for algorithm training to identify onset of COVID-19 using machine learning classification. The algorithm identified COVID-19 an average of 2.75 days before participants sought diagnostic testing with a sensitivity of 82% and specificity of 63%. The receiving operating characteristic (ROC) area under the curve (AUC) was 0.819 (95% CI [0.809, 0.830]). Including continuous temperature yielded an AUC 4.9% higher than without this feature. For further validation, we obtained SARS CoV-2 antibody in a subset of participants and identified 10 additional participants who self-reported COVID-19 disease with antibody confirmation. The algorithm had an overall ROC AUC of 0.819 (95% CI [0.809, 0.830]), with a sensitivity of 90% and specificity of 80% in these additional participants. Finally, we observed substantial variation in accuracy based on age and biological sex. Findings highlight the importance of including temperature assessment, using continuous physiological features for alignment, and including diverse populations in algorithm development to optimize accuracy in COVID-19 detection from wearables.


Assuntos
Temperatura Corporal , COVID-19/diagnóstico , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , COVID-19/virologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/isolamento & purificação , Adulto Jovem
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4179-4182, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-33018918

RESUMO

Motivated by the need for continuous cardiovascular monitoring, we present a system for performing photoplethysmography sensing at multiple facial locations. As a proof-of-concept, our system incorporates an optical sensor array into a wearable face mask form factor for application in a surgical hemodynamic monitoring use case. Here we demonstrate that our design can accurately detect pulse timing by validating estimated heart rate against ground truth electrocardiogram recordings. In an experiment across 10 experimental subjects, our system achieves an error standard deviation of 2.84 beats per minute. This system shows promise for performing non-invasive, continuous pulse waveform recording from multiple locations on the face.


Assuntos
Monitorização Hemodinâmica , Fotopletismografia , Eletrocardiografia , Frequência Cardíaca , Monitorização Fisiológica
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 2333-2336, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29060365

RESUMO

We show that a mobile phone can measure hemoglobin levels using the built-in RGB camera and white LED without modification. Prior work has demonstrated that a smartphone using the built-in RGB camera with the aid of visible and IR lights can achieve a Pearson correlation results between 0.69-0.82 and an RMSE value between 1.26-1.56 g/dL. Our system builds upon the prior work and demonstrates that with only the built-in white LED, the estimation of hemoglobin level has a Pearson correlation of 0.62 with an RMSE of 1.27 g/dL. This extension work demonstrates that it is feasible to measure hemoglobin without using an IR source.


Assuntos
Smartphone , Hemoglobinas